Unfortunately this page does not have a mobile or narrow screen view. Please switch to a desktop computer or increase the size of your browser. For tablets try flipping the screen.

Filters

Applied Filters
2930 data publications found

Experimental insights on electric discharges as a potential mechanism for self-ignition of mud volcanoes

Springsklee, Christina | Manga, Michael | Scheu, Bettina | Cimarelli, Corrado | Dingwell, Donald B.

2022

This data publication provides data from 13 experiments performed in 2022 in the Gas-mixing lab at the Ludwig Maximilian University of Munich (Germany). The experiments were conducted to investigate the charging and discharging potential of material collected from a mud volcano from the...

40Ar/39Ar and paleomagnetic results from Liberia and the Precambrian APW data base for the West African Shield (Dataset)

T.C. Onstott | J. Dorbor

2006

Paleomagnetic, rock magnetic, or geomagnetic data found in the MagIC data repository from a paper titled: 40Ar/39Ar and paleomagnetic results from Liberia and the Precambrian APW data base for the West African Shield

Ring-shear test data of glass beads 200-300 µm used for analogue experiments in the tectonic modelling labs at GFZ Potsdam and the Institute of Geophysics of the Czech Academy of Science, Prague

Rosenau, Matthias | Kemnitz, Helga | Pohlenz, Andre | Warsitzka, Michael | Zavada, Prokop

2022

This dataset provides friction data from ring-shear tests on glass beads with a diameter of 200-300 µm used in analogue modelling of tectonic processes as a rock analogue for “weak” layers in the earth’s upper crust (e.g. Klinkmüller et al., 2016; Ritter et al., 2016; Lohrmann et al., 2003)...

Ring-shear test data of glass beads 100-200 µm used for analogue experiments in the tectonic modelling labs at GFZ Potsdam and the Institute of Geophysics of the Czech Academy of Sciences, Prague

Rosenau, Matthias | Kemnitz, Helga | Pohlenz, Andre | Warsitzka, Michael | Zavada, Prokop

2022

This dataset provides friction data from ring-shear tests on glass beads with a diameter of 100-200 µm used in analogue modelling of tectonic processes as a rock analogue for “weak” layers in the earth’s upper crust (e.g. Klinkmüller et al., 2016; Ritter et al., 2016; Lohrmann et al., 2003)...

Ring-shear test data of glass beads <50 µm used for analogue experiments in the tectonic modelling labs at GFZ Potsdam and the Institute of Geophysics of the Czech Academy of Sciences, Prague

Rudolf, Michael | Rosenau, Matthias | Warsitzka, Michael | Zavada, Prokop

2022

This dataset provides friction data from ring-shear tests on glass beads with a diameter of less than 50 µm used in analogue modelling of tectonic processes as a rock analogue for “weak” layers in the earth’s upper crust (e.g. Klinkmüller et al., 2016; Ritter et al., 2016; Lohrmann et al.,...

Digital image correlation (DIC) and X-Ray CT analyses of lithospheric-scale analogue models of continental rifting

Zwaan, Frank | Schreurs, Guido

2023

This data set includes videos depicting the surface evolution (time-lapse photography, digital image correlation [DIC] analysis, and topography analysis), and internal evolution (X-ray CT-imagery and DIC analysis) of four laboratory experiments (analogue models) simulating lithospheric-scale...

Calibration and Method Validation for Boron (B) Isotope Ratio Measurements performing by ThermoFisher Neptune Plus Mass Spectrometer in the NEPTUNE-TIMS Laboratory (Istituto di Geoscienze e Georisorse, CNR di Pisa)

Di Giuseppe, Paolo | Salvadori, Matteo | Dini, Andrea | Pennisi, Maddalena | Cornacchia, Irene | Vezzoni, Simone | Rielli, Andrea | Agostini, Samuele

2023

A low blank, high-precision, and highly reproducible technique for Boron (B) isotope analysis performed by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer (MC-ICP-MS), Thermo Scientific Neptune PlusTM was developed and is presented here. We show data on a set of international...

Calibration and Method Validation for Strontium (Sr) Isotope Ratio Measurements performing by ThermoFisher Neptune Plus Mass Spectrometer in the NEPTUNE-TIMS Laboratory (Istituto di Geoscienze e Georisorse, CNR di Pisa)

Di Giuseppe, Paolo | Salvadori, Matteo | Dini, Andrea | Pennisi, Maddalena | Cornacchia, Irene | Vezzoni, Simone | Rielli, Andrea | Agostini, Samuele

2023

Results of a high throughput, robust and sensitive method for the precise analysis of 87Sr/86Sr by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer (MC-ICP-MS), Thermo Scientific Neptune PlusTM are reported. The data were obtained after accurate procedures of chemical separation and...

Data underlying the publication: Formulation of tunable size PLGA-PEG nanoparticles for drug delivery using microfluidic technology

Lorenzo Albertazzi | Adrianna Glinkowska

2021

Raw data associated to the article Formulation of tunable size PLGA-PEG nanoparticles for drug delivery using microfluidic technology. The work aims at the use of microfluidic to formulate PLGA particles in a more controlled and automated manner. The data includes the characterisation of...

Calibration and Method Validation for Lead (Pb) Isotope Ratio Measurements performing by ThermoFisher Neptune Plus Mass Spectrometer in the NEPTUNE-TIMS Laboratory (Istituto di Geoscienze e Georisorse, CNR di Pisa)

Di Giuseppe, Paolo | Salvadori, Matteo | Dini, Andrea | Pennisi, Maddalena | Cornacchia, Irene | Vezzoni, Simone | Rielli, Andrea | Agostini, Samuele

2023

We describe here in detail the results and the setup of the high precision Pb isotope ratio analysis performed by Multi Collector Inductively Coupled Plasma Mass Spectrometer (MC ICP MS), Thermo Scientific Neptune Plus TM. We performed this method adding thallium (Tl) as an internal isotopic...