Data Publication

Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample

Stefanie Van Offenwert | Veerle Cnudde | Sharon Ellman | Tom Bultreys

Utrecht University

(2024)

Descriptions

This dataset was used in the study of Van Offenwert et al. (2024). It contains time-resolved laboratory-based micro-CT images of saturated and unsaturated solute injection experiments in sintered glass and Bentheimer sandstone. Based on the grey values in the resolved pore space, pore-scale concentration fields can be quantified. The tracer injection experiments were imaged at 15 s per scan with a voxel size of 13.0 µm (‘Tracer injection experiments’). Each fast imaging experiment was preceded by a higher quality slower pre-scan to determine the static pore structure. All data were acquired with a gantry-based micro-CT system specially designed for in-situ imaging (UGCT). The aim was to analyze pore-scale solute concentration fields to investigate solute spreading and mixing during tracer injection experiments. Further details on the analyses of the micro-CT images can be found in Van Offenwert et al. (2024). The dataset can be used to investigate the influence of pore-scale heterogeneity and the volumetric pump velocity (the Péclet number) on transport processes. The data is provided in 2 subfolders. Detailed information about the files in these subfolders as well as information on how the data is processed is given in the explanatory file ReadMe_Yoda_VanOffenwert.txt. Contact person is Stefanie van Offenwert - stefanie.vanoffenwert@ugent.be.

Keywords


Originally assigned keywords
FOS: Earth and related environmental sciences
Microcomputed Tomography
Non-Fickian solute transport
unsaturated flow and transport
pore-scale imaging
sintered glass
Bentheimer sandstone
micro-CT image
tracer injection experiments
Péclet number

MSL enriched keywords
sedimentary rock
sandstone
Technique
imaging (3D)
computed tomography (CT)

Metadata


MSL enriched sub domains

microscopy and tomography

Resource Type

Research Data


Source


Source publisher

Utrecht University

DOI

10.24416/uu01-l5ltra

Creators

Stefanie Van Offenwert
Personal
Ghent University
Veerle Cnudde
Personal
Utrecht University | Ghent University
Sharon Ellman
Personal
Ghent University
Tom Bultreys
Personal
Ghent University

Citation

Van Offenwert, S., Cnudde, V., Ellman, S., & Bultreys, T. (2024). Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample (Version 1.0) [Data set]. Utrecht University. https://doi.org/10.24416/UU01-L5LTRA


References

URL
References

Dates

Issued 2024-06-28T09:55:02
Updated 2024-07-12T10:53:48
Collected 2020-08-28/2020-09-15

Language

en


Funding References

Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Ghent University Special Research Fund (BOF-UGent)

Rights

Name Open - freely retrievable
URI info:eu-repo/semantics/openAccess
Name Creative Commons Attribution 4.0 International
URI https://creativecommons.org/licenses/by/4.0/legalcode
Identifier cc-by-4.0
Identifier Scheme SPDX
Scheme URI https://spdx.org/licenses/

Locations


Geo location(s)

UGent Core facility UGCT, Ghent, Belgium