Data Publication

Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample

Stefanie Van Offenwert | Veerle Cnudde | Sharon Ellman | Tom Bultreys

Utrecht University

(2024)

Descriptions

This dataset was used in the study of Van Offenwert et al. (2024). It contains time-resolved laboratory-based micro-CT images of saturated and unsaturated solute injection experiments in sintered glass and Bentheimer sandstone. Based on the grey values in the resolved pore space, pore-scale concentration fields can be quantified. The tracer injection experiments were imaged at 15 s per scan with a voxel size of 13.0 µm (‘Tracer injection experiments’). Each fast imaging experiment was preceded by a higher quality slower pre-scan to determine the static pore structure. All data were acquired with a gantry-based micro-CT system specially designed for in-situ imaging (UGCT). The aim was to analyze pore-scale solute concentration fields to investigate solute spreading and mixing during tracer injection experiments. Further details on the analyses of the micro-CT images can be found in Van Offenwert et al. (2024). The dataset can be used to investigate the influence of pore-scale heterogeneity and the volumetric pump velocity (the Péclet number) on transport processes. The data is provided in 2 subfolders. Detailed information about the files in these subfolders as well as information on how the data is processed is given in the explanatory file ReadMe_Yoda_VanOffenwert.txt. Contact person is Stefanie van Offenwert - stefanie.vanoffenwert@ugent.be.

Keywords

MSL enriched keywords
sedimentary rock
sandstone
Technique
imaging (3D)
computed tomography (CT)
Originally assigned keywords
FOS: Earth and related environmental sciences
Microcomputed Tomography
Non-Fickian solute transport
unsaturated flow and transport
pore-scale imaging
sintered glass
Bentheimer sandstone
micro-CT image
tracer injection experiments
Péclet number

Metadata


MSL enriched sub domains

microscopy and tomography

Resource Type

Research Data


Source


Source publisher

Utrecht University

DOI

10.24416/uu01-l5ltra

Creators

Stefanie Van Offenwert
Personal
https://orcid.org/0000-0003-1144-9471
Ghent University
Veerle Cnudde
Personal
https://orcid.org/0000-0002-3269-5914
Utrecht University | Ghent University
Sharon Ellman
Personal
https://orcid.org/0000-0002-1503-4145
Ghent University
Tom Bultreys
Personal
https://orcid.org/0000-0001-8217-8053
Ghent University

Citation

Van Offenwert, S., Cnudde, V., Ellman, S., & Bultreys, T. (2024). Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample (Version 1.0) [Dataset]. Utrecht University. https://doi.org/10.24416/UU01-L5LTRA


References

URL
References

Dates

Issued 2024-06-28T09:55:02
Updated 2024-07-12T10:53:48
Collected 2020-08-28/2020-09-15

Language

en


Funding References

Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Fonds Wetenschappelijk Onderzoek (FWO)
Funder Name Ghent University Special Research Fund (BOF-UGent)

Rights

Name Open - freely retrievable
URI info:eu-repo/semantics/openAccess
Name Creative Commons Attribution 4.0 International
URI https://creativecommons.org/licenses/by/4.0/legalcode
Identifier cc-by-4.0
Identifier Scheme SPDX
Scheme URI https://spdx.org/licenses/

Locations


Geo location(s)

UGent Core facility UGCT, Ghent, Belgium